Retroreflective Mode |
Diffuse Mode |
Through-beam Mode |
| With Filters |
Long Range |
|
Long Range |
| Sensing Object |
≥ø50mm, opaque, translucent or specular object |
≥ø50mm, opaque or translucent object |
Opaque, translucent or transparent object |
≥ø20mm, opaque object (If slit mask are fitted, an object as small as 3x6mm can be detected) |
| Hsterisis |
- |
15% or less of operation distance |
- |
| Repeatability |
0.2mm or less |
0.3mm or less |
0.1mm or less |
0.2mm or less |
| Power Supply |
24 to 240 VAC ± 10% Ripple P-P 10% or less |
| Power Consumption |
2 VA or less |
Emitter: 1 VA or less
Receiver: 2 VA or less |
Emitter: 1.5 VA or less
Receiver: 2 VA or less |
| Output |
| Relay contact 1c |
|
Switching capacity: |
250 VAC 1A (resistive load) |
|
30 VDC 2A (resistive load) |
Electrical life: |
100,000 or more operations (at rated AC load) |
|
50,000 or more operations (at rated DC load) |
Mechanical life: |
100,000 or more operations |
|
| Response Time |
10ms or less |
| Operation Indicator |
Red LED (lights up when the output is ON) |
| Stability Indicator |
Green LED (lights up when the output is ON) |
| Power Indicator |
- |
Red LED (lights up when power is on) |
| Sensitivity Adjuster |
Continuously variable adjuster |
- |
Continuously variable adjuster |
- |
| Interference Immunity |
Incorporated ( Two units of sensors can be mounted closely) |
(use optional interference prevention filters) |
- |
| Pollution Degree |
3 (industrial environment) |
| Enclose Category |
IP66 (IEC) |
| Operating Temperature |
-20 to +55°C (-4°F to 131°F) (No dew or icing allowed) |
| Operating Humidity |
35 to 85% RH |
| Ambient Illuminance |
Sunlight: 11,000l X at the light-receiving face, Incandescent light: 3500l X at the light-receiving face |
| EMC |
IEC 60947-5-2 Parts 7.2.6.1,2,3 or RFI>3V/m (In 30-1000MHz), EFT>1KV, ESD>4KV (contact) |
| Voltage Withstandability |
IEC 60947-5-2 Parts 8.3.3.4, or 500 VDC for one min. between all supply terminals connected together and enclosure |
| Insulation Resistance |
>20M, with 500 VDC megger between all supply terminals |
| Vibration Resistance |
IEC 60947-5-2 Parts 7.4.2 or 10-55 Hz 1.0m amplitude in x, y and z directions for 30 min. |
| Shock Resistance |
IEC 60947-5-2 Parts7.4.1 or 30g 11ms in x, y and z directions for six times each |
| Material |